English
Availability: | |
---|---|
Quantity: | |
Classification and Characteristics
Based on differences in design and performance, commercial inverter heat pumps are mainly classified into normal temperature type and low temperature type, which have significant differences in operating efficiency, structural design, and applicable scenarios.
Parameter/Type | Normal Temperature Heat Pump | Low Temperature Heat Pump |
Operating temperature range | -10℃ to 43℃ | -35℃ to 48℃ |
Applicable environment | It is mainly suitable for regular cooling and heating demands. | It is suitable for applications requiring operation under extreme temperatures. |
Design features | Optimized compressor and heat exchanger design for regular temperature ranges | Additional heating and anti-freeze features to ensure stable performance at very low temperatures |
Energy efficiency ratio (IPLV) | Higher efficiency, suitable for standard energy efficiency requirements. | Slightly lower than normal temperature type, but optimized for low temperatures. |
The most notable characteristic of low-temperature commercial inverter heat pumps is their exceptional energy efficiency. Their unique design features include the adoption of more efficient compressors and enhanced heat exchange technology, as well as special adaptability to high energy efficiency requirements. These features make low-temperature inverter heat pumps perform outstandingly in commercial situations requiring high energy efficiency.
Compact heat pump design with small footprint, optimized piping layout for improved efficiency.
Standardized installation process for quick installation, reducing time and maintenance costs.
Equipped with advanced control systems for real-time environmental monitoring and compressor output adjustment to meet cooling or heating demands.
Product Parameters
Unit mode | LAHR20BM | LAHR20BM | LAHR40BM | LAHR40BM | LAHR60BM | LAHR60BM | |||
Identification Code | RU | RUEG | RU | RUEG | DU | DUEG | |||
Ambient dry/wet bulb temperature | outlet water temperature | capacity | Unit | parameter | parameter | parameter | parameter | parameter | parameter |
35℃/- | 7℃ | Cooling capacity | kW | 29~35 | 31~36 | 58~79 | 60~80 | 118~135 | 120~140 |
power input | kW | 9.69~14 | 9.68~14 | 18.5~29 | 18.6~29 | 37.3~50 | 37.38~50 | ||
COP | kW/kW | 2.5~3.0 | 2.57~3.2 | 2.75~3.2 | 2.75~3.22 | 2.7~3.2 | 2.8~3.21 | ||
7℃/6℃ | 45℃ | heating capacity | kW | 35~53 | 36~55 | 70~107 | 72~108 | 108~162 | 110~165 |
power input | kW | 10~16.6 | 10.08~16.6 | 20~32.8 | 20.5~32.8 | 30.8~53.7 | 31.5~51 | ||
COP | kW/kW | 3.2~3.5 | 3.2~3.57 | 3.26~3.50 | 3.29~3.54 | 3.2~3.50 | 3.23~3.52 | ||
-12℃/- | 50℃ | heating capacity | kW | 24.1~34 | 24.5~35 | 48~68 | 49.5~70 | 75~108 | 76~110 |
power input | kW | 10.9~16.5 | 10.9~16.5 | 21.5~33.3 | 22~33.3 | 33.6~52 | 33.9~52 | ||
COP | kW/kW | 2.06~2.21 | 2.12~2.25 | 2.04~2.23 | 2.10~2.25 | 2.08~2.23 | 2.14~2.24 | ||
-20℃/- | 50℃ | heating capacity | kW | 20~29 | 20.5~30 | 40~57 | 41~58 | 58~92 | 60~93 |
power input | kW | 9.95~15.5 | 9.95~15.5 | 20.7~32 | 21.2~32.5 | 30.1~51 | 30.6~51.3 | ||
COP | kW/kW | 1.87~2.01 | 1.93~2.06 | 1.78~1.93 | 1.82~1.93 | 1.80~1.93 | 1.81~1.96 | ||
IPLV(H)(W55) | kW/kW | 2.33 | 2.33 | 2.26 | 2.26 | 2.38 | 2.38 | ||
IPLV(C) | kW/kW | 3.92 | 3.92 | 4.16 | 4.16 | 4.07 | 4.07 | ||
Water heat exchanger | Form | High-efficiency coaxial type | High-efficiency shell-and-tube type | ||||||
power supply | 3N~380V 50Hz | ||||||||
refrigerant | R410A | R410A | R410A | R410A | R410A | R410A | |||
water flow | m^3/h | 6.2 | 6.2 | 13.76 | 13.76 | 24.08 | 24.08 | ||
Pipe dimension | / | RC1-1/4" | RC1-1/4" | DN50 | DN50 | DN65 | DN65 | ||
water side resistance | kPa | 80 | 80 | 65 | 65 | 80 | 80 | ||
Noise (sound pressure level) | dB(A) | ≤64 | ≤64 | ≤66 | ≤66 | ≤70 | ≤70 | ||
Weight | kg | 450 | 450 | 800 | 850 | 1250 | 1250 | ||
Dimensions | Long | mm | 1060 | 1060 | 2050 | 2050 | 2200 | 2200 | |
Wide | mm | 1010 | 1010 | 1005 | 1005 | 1300 | 1300 | ||
High | mm | 1900 | 1900 | 2090 | 2239 | 2295 | 2295 |
Application
Commercial Cooling and Heating: Commercial inverter heat pumps are widely used in malls, office buildings, and other commercial venues for cooling and heating, making them an ideal choice due to their high efficiency and environmental friendliness.
Hotel Hot Water Supply: Provides stable and efficient hot water supply for hotels, reducing energy consumption and operational costs.
Medical Facilities: In medical facilities, commercial inverter heat pumps provide a constant temperature environment for operating rooms, wards, etc., ensuring the comfort of medical equipment and patients.
Industrial Cooling and Heating: Used in industrial production for cooling and heating processes, enhancing production efficiency and product quality.
Swimming Pool Heating: Provides stable heating for swimming pools to ensure suitable water temperatures and enhance user experience.
Equipment Maintenance Instructions
The controller features a "System Maintenance" function to limit the operating time of the unit. When the system maintenance time is reached, the unit will shut down forcibly and cannot be restarted until the system maintenance is lifted. During system maintenance, the antifreeze function remains unaffected.
The "Cumulative Operating Time of the Unit" is calculated in hours and converted into "days" to determine the system maintenance time (note: this is operating time / 24 hours, not actual days).
When setting the "System Maintenance" function, a system maintenance reminder will be provided to avoid sudden shutdowns causing inconvenience to users.
When the remaining operating time of the unit is more than 168 hours (7 days), the unit operates normally without reminders; when the remaining operating time is less than or equal to 168 hours (7 days), the reminder rule will be triggered.
FAQ
Q: How can I order this product?
A: You can order through our official website, hotline, or email.
Q: What after-sales services do you provide?
A: We offer free on-site installation guidance, equipment debugging, and troubleshooting services.
Q: Do you accept OEM customization?
A: Yes, we accept OEM customization services and can design and produce products according to your needs.
Based on differences in design and performance, commercial inverter heat pumps are mainly classified into normal temperature type and low temperature type, which have significant differences in operating efficiency, structural design, and applicable scenarios.
Parameter/Type | Normal Temperature Heat Pump | Low Temperature Heat Pump |
Operating temperature range | -10℃ to 43℃ | -35℃ to 48℃ |
Applicable environment | It is mainly suitable for regular cooling and heating demands. | It is suitable for applications requiring operation under extreme temperatures. |
Design features | Optimized compressor and heat exchanger design for regular temperature ranges | Additional heating and anti-freeze features to ensure stable performance at very low temperatures |
Energy efficiency ratio (IPLV) | Higher efficiency, suitable for standard energy efficiency requirements. | Slightly lower than normal temperature type, but optimized for low temperatures. |
The most notable characteristic of low-temperature commercial inverter heat pumps is their exceptional energy efficiency. Their unique design features include the adoption of more efficient compressors and enhanced heat exchange technology, as well as special adaptability to high energy efficiency requirements. These features make low-temperature inverter heat pumps perform outstandingly in commercial situations requiring high energy efficiency.
Compact heat pump design with small footprint, optimized piping layout for improved efficiency.
Standardized installation process for quick installation, reducing time and maintenance costs.
Equipped with advanced control systems for real-time environmental monitoring and compressor output adjustment to meet cooling or heating demands.
Unit mode | LAHR20BM | LAHR20BM | LAHR40BM | LAHR40BM | LAHR60BM | LAHR60BM | |||
Identification Code | RU | RUEG | RU | RUEG | DU | DUEG | |||
Ambient dry/wet bulb temperature | outlet water temperature | capacity | Unit | parameter | parameter | parameter | parameter | parameter | parameter |
35℃/- | 7℃ | Cooling capacity | kW | 29~35 | 31~36 | 58~79 | 60~80 | 118~135 | 120~140 |
power input | kW | 9.69~14 | 9.68~14 | 18.5~29 | 18.6~29 | 37.3~50 | 37.38~50 | ||
COP | kW/kW | 2.5~3.0 | 2.57~3.2 | 2.75~3.2 | 2.75~3.22 | 2.7~3.2 | 2.8~3.21 | ||
7℃/6℃ | 45℃ | heating capacity | kW | 35~53 | 36~55 | 70~107 | 72~108 | 108~162 | 110~165 |
power input | kW | 10~16.6 | 10.08~16.6 | 20~32.8 | 20.5~32.8 | 30.8~53.7 | 31.5~51 | ||
COP | kW/kW | 3.2~3.5 | 3.2~3.57 | 3.26~3.50 | 3.29~3.54 | 3.2~3.50 | 3.23~3.52 | ||
-12℃/- | 50℃ | heating capacity | kW | 24.1~34 | 24.5~35 | 48~68 | 49.5~70 | 75~108 | 76~110 |
power input | kW | 10.9~16.5 | 10.9~16.5 | 21.5~33.3 | 22~33.3 | 33.6~52 | 33.9~52 | ||
COP | kW/kW | 2.06~2.21 | 2.12~2.25 | 2.04~2.23 | 2.10~2.25 | 2.08~2.23 | 2.14~2.24 | ||
-20℃/- | 50℃ | heating capacity | kW | 20~29 | 20.5~30 | 40~57 | 41~58 | 58~92 | 60~93 |
power input | kW | 9.95~15.5 | 9.95~15.5 | 20.7~32 | 21.2~32.5 | 30.1~51 | 30.6~51.3 | ||
COP | kW/kW | 1.87~2.01 | 1.93~2.06 | 1.78~1.93 | 1.82~1.93 | 1.80~1.93 | 1.81~1.96 | ||
IPLV(H)(W55) | kW/kW | 2.33 | 2.33 | 2.26 | 2.26 | 2.38 | 2.38 | ||
IPLV(C) | kW/kW | 3.92 | 3.92 | 4.16 | 4.16 | 4.07 | 4.07 | ||
Water heat exchanger | Form | High-efficiency coaxial type | High-efficiency shell-and-tube type | ||||||
power supply | 3N~380V 50Hz | ||||||||
refrigerant | R410A | R410A | R410A | R410A | R410A | R410A | |||
water flow | m^3/h | 6.2 | 6.2 | 13.76 | 13.76 | 24.08 | 24.08 | ||
Pipe dimension | / | RC1-1/4" | RC1-1/4" | DN50 | DN50 | DN65 | DN65 | ||
water side resistance | kPa | 80 | 80 | 65 | 65 | 80 | 80 | ||
Noise (sound pressure level) | dB(A) | ≤64 | ≤64 | ≤66 | ≤66 | ≤70 | ≤70 | ||
Weight | kg | 450 | 450 | 800 | 850 | 1250 | 1250 | ||
Dimensions | Long | mm | 1060 | 1060 | 2050 | 2050 | 2200 | 2200 | |
Wide | mm | 1010 | 1010 | 1005 | 1005 | 1300 | 1300 | ||
High | mm | 1900 | 1900 | 2090 | 2239 | 2295 | 2295 |
Commercial Cooling and Heating: Commercial inverter heat pumps are widely used in malls, office buildings, and other commercial venues for cooling and heating, making them an ideal choice due to their high efficiency and environmental friendliness.
Hotel Hot Water Supply: Provides stable and efficient hot water supply for hotels, reducing energy consumption and operational costs.
Medical Facilities: In medical facilities, commercial inverter heat pumps provide a constant temperature environment for operating rooms, wards, etc., ensuring the comfort of medical equipment and patients.
Industrial Cooling and Heating: Used in industrial production for cooling and heating processes, enhancing production efficiency and product quality.
Swimming Pool Heating: Provides stable heating for swimming pools to ensure suitable water temperatures and enhance user experience.
The controller features a "System Maintenance" function to limit the operating time of the unit. When the system maintenance time is reached, the unit will shut down forcibly and cannot be restarted until the system maintenance is lifted. During system maintenance, the antifreeze function remains unaffected.
The "Cumulative Operating Time of the Unit" is calculated in hours and converted into "days" to determine the system maintenance time (note: this is operating time / 24 hours, not actual days).
When setting the "System Maintenance" function, a system maintenance reminder will be provided to avoid sudden shutdowns causing inconvenience to users.
When the remaining operating time of the unit is more than 168 hours (7 days), the unit operates normally without reminders; when the remaining operating time is less than or equal to 168 hours (7 days), the reminder rule will be triggered.
Q: How can I order this product?
A: You can order through our official website, hotline, or email.
Q: What after-sales services do you provide?
A: We offer free on-site installation guidance, equipment debugging, and troubleshooting services.
Q: Do you accept OEM customization?
A: Yes, we accept OEM customization services and can design and produce products according to your needs.
content is empty!