English
Availability: | |
---|---|
Quantity: | |
Characteristics
These units feature a compact yet sturdy design, optimizing floor space utilization while incorporating an enhanced ductwork layout to improve air circulation efficiency.
Standardized installation procedures facilitate quick and easy setup, minimizing installation time and maintenance costs.
The intelligent control system monitors indoor environmental changes in real-time, automatically adjusting parameters such as air supply volume, temperature, and humidity to cater to different scenarios.
Product Parameters
Model | Air volume | Number of coil rows | Fresh air condition | Return air condition | Inlet and outlet pipe diameter | Condensate pipe diameter | ||||
Cooling capacity | Heating capacity | Water discharge | Cooling capacity | Heating capacity | Water discharge | |||||
VFC(S) | m³/h | R | kW | kW | L/S | kW | kW | L/S | DN | DN |
015 | 1500 | 4 | 18.6 | 19.7 | 0.9 | 9.3 | 16.7 | 0.5 | 32 | 32 |
6 | 23.4 | 22.5 | 1.2 | 11.7 | 18.9 | 0.6 | ||||
8 | 25.5 | 25.2 | 1.3 | 12.8 | 23.7 | 0.7 | ||||
020 | 2000 | 4 | 24.8 | 26.2 | 1.2 | 12.4 | 22.2 | 0.6 | 32 | 32 |
6 | 31.2 | 30.0 | 1.5 | 15.6 | 25.2 | 0.8 | ||||
8 | 34.0 | 33.6 | 1.7 | 17.0 | 31.6 | 0.9 | ||||
025 | 2500 | 4 | 31.0 | 32.8 | 1.5 | 15.5 | 27.8 | 0.8 | 32 | 32 |
6 | 39.0 | 37.5 | 1.9 | 19.5 | 31.5 | 1.0 | ||||
8 | 42.5 | 42.0 | 2.1 | 21.3 | 39.5 | 1.1 | ||||
030 | 3000 | 4 | 37.2 | 39.3 | 1.8 | 18.6 | 33.3 | 0.9 | 32 | 32 |
6 | 46.8 | 45.0 | 2.3 | 23.4 | 37.8 | 1.2 | ||||
8 | 51.0 | 50.4 | 2.5 | 25.5 | 47.4 | 1.3 | ||||
040 | 4000 | 4 | 49.6 | 52.4 | 2.4 | 24.8 | 44.4 | 1.2 | 40 | 32 |
6 | 62.4 | 60.0 | 3.0 | 31.2 | 50.4 | 1.5 | ||||
8 | 68.0 | 67.2 | 3.3 | 34.0 | 63.2 | 1.7 | ||||
050 | 5000 | 4 | 62.0 | 65.5 | 3.0 | 31.0 | 55.5 | 1.5 | 40 | 32 |
6 | 78.0 | 75.0 | 3.8 | 39.0 | 63.0 | 1.9 | ||||
8 | 85.0 | 84.0 | 4.1 | 42.5 | 79.0 | 2.1 | ||||
060 | 6000 | 4 | 74.4 | 78.6 | 3.6 | 37.2 | 66.6 | 1.8 | 40 | 32 |
6 | 93.6 | 90.0 | 4.5 | 46.8 | 75.6 | 2.3 | ||||
8 | 102.0 | 100.8 | 4.9 | 51.0 | 94.8 | 2.5 | ||||
070 | 7000 | 4 | 86.8 | 91.7 | 4.2 | 43.4 | 77.7 | 2.1 | 50 | 32 |
6 | 109.2 | 105.0 | 5.3 | 54.6 | 88.2 | 2.7 | ||||
8 | 119.0 | 117.6 | 5.7 | 59.5 | 110.6 | 2.9 | ||||
080 | 8000 | 4 | 99.2 | 104.8 | 4.8 | 49.6 | 88.8 | 2.4 | 50 | 32 |
6 | 124.8 | 120.0 | 6.0 | 62.4 | 100.8 | 3.0 | ||||
8 | 136.0 | 134.4 | 6.5 | 68.0 | 126.4 | 3.3 | ||||
100 | 10000 | 4 | 124.0 | 131.0 | 6.0 | 62.0 | 111.0 | 3.0 | 65 | 32 |
6 | 156.0 | 150.0 | 7.5 | 78.0 | 126.0 | 3.8 | ||||
8 | 170.0 | 168.0 | 8.2 | 85.0 | 158.0 | 4.1 | ||||
120 | 12000 | 4 | 148.8 | 157.2 | 7.2 | 74.4 | 133.2 | 3.6 | 65 | 32 |
6 | 187.2 | 180.0 | 9.0 | 93.6 | 151.2 | 4.5 | ||||
8 | 204.0 | 201.6 | 9.8 | 102.0 | 189.6 | 4.9 | ||||
135 | 13500 | 4 | 167.4 | 176.9 | 8.0 | 83.7 | 149.9 | 4.0 | 65 | 32 |
6 | 210.6 | 202.5 | 10.1 | 105.3 | 170.1 | 5.1 | ||||
8 | 229.5 | 226.8 | 11.0 | 114.8 | 213.3 | 5.5 | ||||
150 | 15000 | 4 | 186.0 | 196.5 | 8.9 | 93.0 | 166.5 | 4.5 | 65 | 32 |
6 | 234.0 | 225.0 | 11.2 | 117.0 | 189.0 | 5.6 | ||||
8 | 255.0 | 252.0 | 12.2 | 127.5 | 237.0 | 6.1 |
Application
Commercial Buildings: Floor-standing air handling units are ideal for large commercial spaces such as shopping malls, exhibition halls, and conference centers. They provide effective ventilation and air conditioning, ensuring a comfortable environment for visitors and staff.
Industrial Facilities: In industrial settings, these units are often used in manufacturing plants, warehouses, and laboratories. They help maintain a consistent indoor climate, reducing the impact of external conditions on production processes and sensitive equipment.
Educational Institutions: Schools, universities, and training centers benefit from floor-standing air handling units that ensure a healthy and productive learning environment. They provide adequate ventilation to keep classrooms and lecture halls fresh and comfortable.
Healthcare Facilities: Hospitals, clinics, and rehabilitation centers require air handling units that can maintain a sterile and comfortable atmosphere. Floor-standing units offer advanced filtration and humidity control, reducing the risk of infection and improving patient outcomes.
Residential Buildings: In multi-story residential buildings, floor-standing air handling units provide centralized ventilation and air conditioning for apartments and condos. They ensure a consistent indoor climate across different floors and units.
Equipment Maintenance Instructions
Before the installation of the unit, check whether the unit is damaged in detail. If there are any of the following situations, please contact the after-sales service for repair and replacement:
In order to be safe, the unit of the suspended ceiling must be solid when lifting, the unit must be lifted as (below), or be loaded and unloaded by forklift. The lifting point should be strong and strong enough to bear the weight of the unit and ensure the level of the unit.
Before wiring, check whether the power supply is consistent with the unit nameplate, and the power supply voltage deviation does not exceed ±10 % of the rated voltage. Before starting the fan, it is necessary to enter the unit and rotate the fan impeller by hand, carefully check whether there is metal friction sound, if there is an anomaly, it should be excluded. After the power is connected, start the fan and check whether the rotation direction of the impeller is correct. If it is found that the steering is wrong, just change the phase sequence of the power supply line.
It is recommended to set a plenum at the inlet and outlet of the unit, set an air volume regulating valve on the air duct, and set a fire valve according to fire fighting requirements. If the electric air volume regulating valve is installed, the air valve actuator should be opened before the fan and closed after the fan.
Before connecting the water pipe, pay attention to cleaning the water pipe.
FAQ
Q: How can we purchase this product?
A: You can make purchase inquiries and place orders through our official website or by contacting our customer service representatives.
Q: What after-sales services do you provide?
A: We offer comprehensive after-sales services, including equipment installation guidance, troubleshooting, and repairs, to ensure the stable operation of your equipment.
Q: Do you support customized services?
A: Yes, we do. You can communicate your specific needs and site conditions with us to customize a floor-standing air handling unit that suits your requirements.
These units feature a compact yet sturdy design, optimizing floor space utilization while incorporating an enhanced ductwork layout to improve air circulation efficiency.
Standardized installation procedures facilitate quick and easy setup, minimizing installation time and maintenance costs.
The intelligent control system monitors indoor environmental changes in real-time, automatically adjusting parameters such as air supply volume, temperature, and humidity to cater to different scenarios.
Model | Air volume | Number of coil rows | Fresh air condition | Return air condition | Inlet and outlet pipe diameter | Condensate pipe diameter | ||||
Cooling capacity | Heating capacity | Water discharge | Cooling capacity | Heating capacity | Water discharge | |||||
VFC(S) | m³/h | R | kW | kW | L/S | kW | kW | L/S | DN | DN |
015 | 1500 | 4 | 18.6 | 19.7 | 0.9 | 9.3 | 16.7 | 0.5 | 32 | 32 |
6 | 23.4 | 22.5 | 1.2 | 11.7 | 18.9 | 0.6 | ||||
8 | 25.5 | 25.2 | 1.3 | 12.8 | 23.7 | 0.7 | ||||
020 | 2000 | 4 | 24.8 | 26.2 | 1.2 | 12.4 | 22.2 | 0.6 | 32 | 32 |
6 | 31.2 | 30.0 | 1.5 | 15.6 | 25.2 | 0.8 | ||||
8 | 34.0 | 33.6 | 1.7 | 17.0 | 31.6 | 0.9 | ||||
025 | 2500 | 4 | 31.0 | 32.8 | 1.5 | 15.5 | 27.8 | 0.8 | 32 | 32 |
6 | 39.0 | 37.5 | 1.9 | 19.5 | 31.5 | 1.0 | ||||
8 | 42.5 | 42.0 | 2.1 | 21.3 | 39.5 | 1.1 | ||||
030 | 3000 | 4 | 37.2 | 39.3 | 1.8 | 18.6 | 33.3 | 0.9 | 32 | 32 |
6 | 46.8 | 45.0 | 2.3 | 23.4 | 37.8 | 1.2 | ||||
8 | 51.0 | 50.4 | 2.5 | 25.5 | 47.4 | 1.3 | ||||
040 | 4000 | 4 | 49.6 | 52.4 | 2.4 | 24.8 | 44.4 | 1.2 | 40 | 32 |
6 | 62.4 | 60.0 | 3.0 | 31.2 | 50.4 | 1.5 | ||||
8 | 68.0 | 67.2 | 3.3 | 34.0 | 63.2 | 1.7 | ||||
050 | 5000 | 4 | 62.0 | 65.5 | 3.0 | 31.0 | 55.5 | 1.5 | 40 | 32 |
6 | 78.0 | 75.0 | 3.8 | 39.0 | 63.0 | 1.9 | ||||
8 | 85.0 | 84.0 | 4.1 | 42.5 | 79.0 | 2.1 | ||||
060 | 6000 | 4 | 74.4 | 78.6 | 3.6 | 37.2 | 66.6 | 1.8 | 40 | 32 |
6 | 93.6 | 90.0 | 4.5 | 46.8 | 75.6 | 2.3 | ||||
8 | 102.0 | 100.8 | 4.9 | 51.0 | 94.8 | 2.5 | ||||
070 | 7000 | 4 | 86.8 | 91.7 | 4.2 | 43.4 | 77.7 | 2.1 | 50 | 32 |
6 | 109.2 | 105.0 | 5.3 | 54.6 | 88.2 | 2.7 | ||||
8 | 119.0 | 117.6 | 5.7 | 59.5 | 110.6 | 2.9 | ||||
080 | 8000 | 4 | 99.2 | 104.8 | 4.8 | 49.6 | 88.8 | 2.4 | 50 | 32 |
6 | 124.8 | 120.0 | 6.0 | 62.4 | 100.8 | 3.0 | ||||
8 | 136.0 | 134.4 | 6.5 | 68.0 | 126.4 | 3.3 | ||||
100 | 10000 | 4 | 124.0 | 131.0 | 6.0 | 62.0 | 111.0 | 3.0 | 65 | 32 |
6 | 156.0 | 150.0 | 7.5 | 78.0 | 126.0 | 3.8 | ||||
8 | 170.0 | 168.0 | 8.2 | 85.0 | 158.0 | 4.1 | ||||
120 | 12000 | 4 | 148.8 | 157.2 | 7.2 | 74.4 | 133.2 | 3.6 | 65 | 32 |
6 | 187.2 | 180.0 | 9.0 | 93.6 | 151.2 | 4.5 | ||||
8 | 204.0 | 201.6 | 9.8 | 102.0 | 189.6 | 4.9 | ||||
135 | 13500 | 4 | 167.4 | 176.9 | 8.0 | 83.7 | 149.9 | 4.0 | 65 | 32 |
6 | 210.6 | 202.5 | 10.1 | 105.3 | 170.1 | 5.1 | ||||
8 | 229.5 | 226.8 | 11.0 | 114.8 | 213.3 | 5.5 | ||||
150 | 15000 | 4 | 186.0 | 196.5 | 8.9 | 93.0 | 166.5 | 4.5 | 65 | 32 |
6 | 234.0 | 225.0 | 11.2 | 117.0 | 189.0 | 5.6 | ||||
8 | 255.0 | 252.0 | 12.2 | 127.5 | 237.0 | 6.1 |
Commercial Buildings: Floor-standing air handling units are ideal for large commercial spaces such as shopping malls, exhibition halls, and conference centers. They provide effective ventilation and air conditioning, ensuring a comfortable environment for visitors and staff.
Industrial Facilities: In industrial settings, these units are often used in manufacturing plants, warehouses, and laboratories. They help maintain a consistent indoor climate, reducing the impact of external conditions on production processes and sensitive equipment.
Educational Institutions: Schools, universities, and training centers benefit from floor-standing air handling units that ensure a healthy and productive learning environment. They provide adequate ventilation to keep classrooms and lecture halls fresh and comfortable.
Healthcare Facilities: Hospitals, clinics, and rehabilitation centers require air handling units that can maintain a sterile and comfortable atmosphere. Floor-standing units offer advanced filtration and humidity control, reducing the risk of infection and improving patient outcomes.
Residential Buildings: In multi-story residential buildings, floor-standing air handling units provide centralized ventilation and air conditioning for apartments and condos. They ensure a consistent indoor climate across different floors and units.
Before the installation of the unit, check whether the unit is damaged in detail. If there are any of the following situations, please contact the after-sales service for repair and replacement:
In order to be safe, the unit of the suspended ceiling must be solid when lifting, the unit must be lifted as (below), or be loaded and unloaded by forklift. The lifting point should be strong and strong enough to bear the weight of the unit and ensure the level of the unit.
Before wiring, check whether the power supply is consistent with the unit nameplate, and the power supply voltage deviation does not exceed ±10 % of the rated voltage. Before starting the fan, it is necessary to enter the unit and rotate the fan impeller by hand, carefully check whether there is metal friction sound, if there is an anomaly, it should be excluded. After the power is connected, start the fan and check whether the rotation direction of the impeller is correct. If it is found that the steering is wrong, just change the phase sequence of the power supply line.
It is recommended to set a plenum at the inlet and outlet of the unit, set an air volume regulating valve on the air duct, and set a fire valve according to fire fighting requirements. If the electric air volume regulating valve is installed, the air valve actuator should be opened before the fan and closed after the fan.
Before connecting the water pipe, pay attention to cleaning the water pipe.
Q: How can we purchase this product?
A: You can make purchase inquiries and place orders through our official website or by contacting our customer service representatives.
Q: What after-sales services do you provide?
A: We offer comprehensive after-sales services, including equipment installation guidance, troubleshooting, and repairs, to ensure the stable operation of your equipment.
Q: Do you support customized services?
A: Yes, we do. You can communicate your specific needs and site conditions with us to customize a floor-standing air handling unit that suits your requirements.
content is empty!