Rooftop air conditioning unit is a commercial air conditioning system integrating refrigeration, heating and ventilation, which is usually installed on the roof of buildings and is suitable for the temperature control requirements of medium and large spaces. Its modular design supports flexible adaptation to different building structures and is widely used in commercial, industrial and public facilities.
  • VOLKS

Availability:
Quantity:

Structure and working principle

Core structure

  • Compressor: Drive the refrigerant circulation to realize heat exchange.

  • Evaporator and condenser: responsible for absorbing and releasing heat respectively.

  • Fan system: built-in centrifugal fan transports the treated air.

  • Filter device: Purify air, with optional high-efficiency filter.

  • Control system: integrated temperature and humidity sensor and intelligent control panel.

Principle of operation

  • Refrigeration mode: the refrigerant absorbs indoor heat in the evaporator, is compressed by the compressor, and is discharged outside the condenser.

  • Heating mode (heat pump type): Switch the refrigerant flow direction through the four-way valve to realize reverse circulation.

  • Ventilation mode: external air is introduced by an external fresh air system, mixed and filtered and sent indoors.

Product advantages and application scenarios

Product advantage

  • High efficiency and energy saving: frequency conversion compressor and EC fan are adopted, and the energy efficiency ratio (EER) is above 3.5.

  • Save space: the roof installation does not occupy indoor area, which is suitable for space-limited scenes.

  • Intelligent control: Support remote monitoring of Internet of Things (IoT) and automatically adjust operation parameters.

  • Low maintenance cost: modular design is convenient for disassembly and maintenance, and filter screen replacement is convenient.

  • Strong environmental adaptability: the shell is made of anti-corrosion material, which can run at -20℃ to 50℃.

Application scenario

  • Commercial buildings: shopping malls, supermarkets, hotel banquet halls.

  • Industrial facilities: workshops, warehouses and logistics centers.

  • Public institutions: gymnasium, exhibition hall, school auditorium.

Technical parameters

MODELWRF28ZAWRF30ZAWRF32ZAWRF36ZAWRF42ZAWRF48ZAWRF55ZAWRF64ZA
Cooling CapacitykW28.829.932.435.641.647.253.263.3
Heating CapacitykW31.132.334.63844.650.256.467
Control Range%0、50、
100
54、100
0、46、
0、50、
100
0、50、
100
63、100
0、37、
68、100
0、32、
60、100
0、40、
0、50、
100
Power Supply380V / 3Ph / 50Hz
Cooling Power InputkW11.0311.612.413.1414.816.971922.21
Heating Power InputkW10.410.811.5712.0313.7615.7917.419.88
Start CurrentA62.562.959.975.387.9103.9108111.4
Cooling CurrentA1718.519.623.127.930.933.739
Heating CurrentA15.617.217.821.626.128.731.336.5
Throttling MethodThermal Expansion Valve
System Qty12
RefrigerantR410A
Condenser
Fan MotorAxial fan power supply380V / 3Ph / 50HAZ
Qty11122222
Speedr/min920710940720920920920720
Driver TypeDirect drive
Power InputkW0.550.550.552x0.372x0.452x0.552x0.552x0.75
Air Flowm /h31230012300123001420018800188002140028400
Evaporator
Fan MotorCentrifugal fan power supply380V / 3Ph / 50HAZ
Qty11111111
(High/medium/low) fan speedr/min1320140011209409401000750750
Power InputkW1.11.51.52.22.2334
Air Flowm /h34700540063006800790095001000012500
Driver TypeDrive pulley
ESP(Pa)235305290270250250250250
FilterNylon filter
Noise dB(A)7072727272757373
refrigerant charge(kg)78.292x5.38+4.29+4.210.5+4.22x9
DimensionLengthmm19402240224025402540254024902490
Widthmm13901390139018601860186020502210
Heightmm10451045104510451195119513901490
Weightkg460500520650755770810890
Note:
Cooling Capacity Running Conditioning: Indoor temperature 27/19, Outdoor temperature 35/24
Heating Capacity Running Conditioning: Indoor temperature 20/15, Outdoor temperature 7/6


FAQ

Q: Is it necessary to reinforce the building structure when installing roof units?

A: It needs to be evaluated according to the weight of the unit. Usually, the bearing capacity per square meter needs to be ≥300kg, so it is recommended to be tested by a professional team.


Q: What is the heating effect in winter?

A: Heat pump units can operate normally above -15℃, and auxiliary electric heating is recommended in extremely cold areas.


Q: Will noise affect the surrounding environment?

A: totally enclosed scroll compressor+shock absorption design, with noise ≤65dB(A) during operation, which meets the standards of business district.

Quick Links

Product Category

About VOLKS

Resources

Contact Us

 Email: james@sdvolksgroup.com
 Tel: +86-18315978656
 WhatsApp: +8613310606210
Address: East Tianqu Road, Zhongao Street, Economic and Technological Development Zone, Dezhou city, Shandong province, China. 253000
Copyright © 2024 Shandong VOLKS Air Conditioning Group Co., Ltd. All Rights Reserved. Sitemap. Privacy Policy.