English
VOLKS
Availability: | |
---|---|
Quantity: | |
Structure and working principle
Structure and working principle
Integrated design: the functions of refrigeration, heating and air supply are integrated into a single device, and air is evenly supplied to the room through the air duct.
Intelligent collaborative operation:Refrigeration cycle: outdoor high-temperature air → condenser heat dissipation → refrigerant enters evaporator to absorb indoor heat after cooling.
Heating cycle: the four-way valve switches the flow direction, the condenser turns to heat release, and the evaporator absorbs outdoor heat (heat pump models only).
Fresh air mixing: All-heat exchanger can be selected to introduce fresh air and reduce energy loss.
Product advantages and application scenarios
Product advantage
Peace of mind and electricity saving: first-class energy efficiency certification, saving 30% electricity bill compared with traditional split air conditioners.
Ready-to-use: the pipeline is pre-assembled in the factory, and the site only needs to be connected with electricity and air pipes, which shortens the construction period by 50%.
Quiet and comfortable: Night mode can reduce the noise to below 50dB, suitable for 24-hour business premises.
Long-term durability: the core components are guaranteed for 5 years and the design life is 15 years.
Environmental protection: compatible with R410A/R32 environmental protection refrigerant, reducing carbon footprint.
Application scenario
Retail industry: large supermarkets and brand flagship stores (stable temperature and humidity protection products).
Manufacturing: electronic workshop, food processing factory (need accurate temperature control, moisture and dust prevention).
Service industry: data center, hospital (round-the-clock operation demand).
Technical parameters
MODEL | WRF28ZA | WRF30ZA | WRF32ZA | WRF36ZA | WRF42ZA | WRF48ZA | WRF55ZA | WRF64ZA | ||
Cooling Capacity | kW | 28.8 | 29.9 | 32.4 | 35.6 | 41.6 | 47.2 | 53.2 | 63.3 | |
Heating Capacity | kW | 31.1 | 32.3 | 34.6 | 38 | 44.6 | 50.2 | 56.4 | 67 | |
Control Range | % | 0、50、 100 | 54、100 0、46、 | 0、50、 100 | 0、50、 100 | 63、100 0、37、 | 68、100 0、32、 | 60、100 0、40、 | 0、50、 100 | |
Power Supply | 380V / 3Ph / 50Hz | |||||||||
Cooling Power Input | kW | 11.03 | 11.6 | 12.4 | 13.14 | 14.8 | 16.97 | 19 | 22.21 | |
Heating Power Input | kW | 10.4 | 10.8 | 11.57 | 12.03 | 13.76 | 15.79 | 17.4 | 19.88 | |
Start Current | A | 62.5 | 62.9 | 59.9 | 75.3 | 87.9 | 103.9 | 108 | 111.4 | |
Cooling Current | A | 17 | 18.5 | 19.6 | 23.1 | 27.9 | 30.9 | 33.7 | 39 | |
Heating Current | A | 15.6 | 17.2 | 17.8 | 21.6 | 26.1 | 28.7 | 31.3 | 36.5 | |
Throttling Method | Thermal Expansion Valve | |||||||||
System Qty | 1 | 2 | ||||||||
Refrigerant | R410A | |||||||||
Condenser | ||||||||||
Fan Motor | Axial fan power supply | 380V / 3Ph / 50HAZ | ||||||||
Qty | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | ||
Speed | r/min | 920 | 710 | 940 | 720 | 920 | 920 | 920 | 720 | |
Driver Type | Direct drive | |||||||||
Power Input | kW | 0.55 | 0.55 | 0.55 | 2x0.37 | 2x0.45 | 2x0.55 | 2x0.55 | 2x0.75 | |
Air Flow | m /h3 | 12300 | 12300 | 12300 | 14200 | 18800 | 18800 | 21400 | 28400 | |
Evaporator | ||||||||||
Fan Motor | Centrifugal fan power supply | 380V / 3Ph / 50HAZ | ||||||||
Qty | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||
(High/medium/low) fan speed | r/min | 1320 | 1400 | 1120 | 940 | 940 | 1000 | 750 | 750 | |
Power Input | kW | 1.1 | 1.5 | 1.5 | 2.2 | 2.2 | 3 | 3 | 4 | |
Air Flow | m /h3 | 4700 | 5400 | 6300 | 6800 | 7900 | 9500 | 10000 | 12500 | |
Driver Type | Drive pulley | |||||||||
ESP(Pa) | 235 | 305 | 290 | 270 | 250 | 250 | 250 | 250 | ||
Filter | Nylon filter | |||||||||
Noise dB(A) | 70 | 72 | 72 | 72 | 72 | 75 | 73 | 73 | ||
refrigerant charge(kg) | 7 | 8.2 | 9 | 2x5.3 | 8+4.2 | 9+4.2 | 10.5+4.2 | 2x9 | ||
Dimension | Length | mm | 1940 | 2240 | 2240 | 2540 | 2540 | 2540 | 2490 | 2490 |
Width | mm | 1390 | 1390 | 1390 | 1860 | 1860 | 1860 | 2050 | 2210 | |
Height | mm | 1045 | 1045 | 1045 | 1045 | 1195 | 1195 | 1390 | 1490 | |
Weight | kg | 460 | 500 | 520 | 650 | 755 | 770 | 810 | 890 | |
Note: Cooling Capacity Running Conditioning: Indoor temperature 27/19, Outdoor temperature 35/24 Heating Capacity Running Conditioning: Indoor temperature 20/15, Outdoor temperature 7/6 |
FAQ
Q: Is it safe to install in typhoon area?
A: The unit has passed the wind pressure test (it can resist the typhoon of class 12), and it is fixed with anchor bolts as standard, with high safety.
Q: Is it compatible with the existing central air conditioning system?
A: It supports Modbus communication protocol, and can be connected to the building automation system (BAS) for unified management.
Q: How long does the filter need to be replaced?
A: The primary filter screen should be cleaned every 3 months, and the high-efficiency filter screen (such as HEPA) is recommended to be replaced every year, depending on the use environment.
Structure and working principle
Integrated design: the functions of refrigeration, heating and air supply are integrated into a single device, and air is evenly supplied to the room through the air duct.
Intelligent collaborative operation:Refrigeration cycle: outdoor high-temperature air → condenser heat dissipation → refrigerant enters evaporator to absorb indoor heat after cooling.
Heating cycle: the four-way valve switches the flow direction, the condenser turns to heat release, and the evaporator absorbs outdoor heat (heat pump models only).
Fresh air mixing: All-heat exchanger can be selected to introduce fresh air and reduce energy loss.
Product advantage
Peace of mind and electricity saving: first-class energy efficiency certification, saving 30% electricity bill compared with traditional split air conditioners.
Ready-to-use: the pipeline is pre-assembled in the factory, and the site only needs to be connected with electricity and air pipes, which shortens the construction period by 50%.
Quiet and comfortable: Night mode can reduce the noise to below 50dB, suitable for 24-hour business premises.
Long-term durability: the core components are guaranteed for 5 years and the design life is 15 years.
Environmental protection: compatible with R410A/R32 environmental protection refrigerant, reducing carbon footprint.
Application scenario
Retail industry: large supermarkets and brand flagship stores (stable temperature and humidity protection products).
Manufacturing: electronic workshop, food processing factory (need accurate temperature control, moisture and dust prevention).
Service industry: data center, hospital (round-the-clock operation demand).
MODEL | WRF28ZA | WRF30ZA | WRF32ZA | WRF36ZA | WRF42ZA | WRF48ZA | WRF55ZA | WRF64ZA | ||
Cooling Capacity | kW | 28.8 | 29.9 | 32.4 | 35.6 | 41.6 | 47.2 | 53.2 | 63.3 | |
Heating Capacity | kW | 31.1 | 32.3 | 34.6 | 38 | 44.6 | 50.2 | 56.4 | 67 | |
Control Range | % | 0、50、 100 | 54、100 0、46、 | 0、50、 100 | 0、50、 100 | 63、100 0、37、 | 68、100 0、32、 | 60、100 0、40、 | 0、50、 100 | |
Power Supply | 380V / 3Ph / 50Hz | |||||||||
Cooling Power Input | kW | 11.03 | 11.6 | 12.4 | 13.14 | 14.8 | 16.97 | 19 | 22.21 | |
Heating Power Input | kW | 10.4 | 10.8 | 11.57 | 12.03 | 13.76 | 15.79 | 17.4 | 19.88 | |
Start Current | A | 62.5 | 62.9 | 59.9 | 75.3 | 87.9 | 103.9 | 108 | 111.4 | |
Cooling Current | A | 17 | 18.5 | 19.6 | 23.1 | 27.9 | 30.9 | 33.7 | 39 | |
Heating Current | A | 15.6 | 17.2 | 17.8 | 21.6 | 26.1 | 28.7 | 31.3 | 36.5 | |
Throttling Method | Thermal Expansion Valve | |||||||||
System Qty | 1 | 2 | ||||||||
Refrigerant | R410A | |||||||||
Condenser | ||||||||||
Fan Motor | Axial fan power supply | 380V / 3Ph / 50HAZ | ||||||||
Qty | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | ||
Speed | r/min | 920 | 710 | 940 | 720 | 920 | 920 | 920 | 720 | |
Driver Type | Direct drive | |||||||||
Power Input | kW | 0.55 | 0.55 | 0.55 | 2x0.37 | 2x0.45 | 2x0.55 | 2x0.55 | 2x0.75 | |
Air Flow | m /h3 | 12300 | 12300 | 12300 | 14200 | 18800 | 18800 | 21400 | 28400 | |
Evaporator | ||||||||||
Fan Motor | Centrifugal fan power supply | 380V / 3Ph / 50HAZ | ||||||||
Qty | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||
(High/medium/low) fan speed | r/min | 1320 | 1400 | 1120 | 940 | 940 | 1000 | 750 | 750 | |
Power Input | kW | 1.1 | 1.5 | 1.5 | 2.2 | 2.2 | 3 | 3 | 4 | |
Air Flow | m /h3 | 4700 | 5400 | 6300 | 6800 | 7900 | 9500 | 10000 | 12500 | |
Driver Type | Drive pulley | |||||||||
ESP(Pa) | 235 | 305 | 290 | 270 | 250 | 250 | 250 | 250 | ||
Filter | Nylon filter | |||||||||
Noise dB(A) | 70 | 72 | 72 | 72 | 72 | 75 | 73 | 73 | ||
refrigerant charge(kg) | 7 | 8.2 | 9 | 2x5.3 | 8+4.2 | 9+4.2 | 10.5+4.2 | 2x9 | ||
Dimension | Length | mm | 1940 | 2240 | 2240 | 2540 | 2540 | 2540 | 2490 | 2490 |
Width | mm | 1390 | 1390 | 1390 | 1860 | 1860 | 1860 | 2050 | 2210 | |
Height | mm | 1045 | 1045 | 1045 | 1045 | 1195 | 1195 | 1390 | 1490 | |
Weight | kg | 460 | 500 | 520 | 650 | 755 | 770 | 810 | 890 | |
Note: Cooling Capacity Running Conditioning: Indoor temperature 27/19, Outdoor temperature 35/24 Heating Capacity Running Conditioning: Indoor temperature 20/15, Outdoor temperature 7/6 |
Q: Is it safe to install in typhoon area?
A: The unit has passed the wind pressure test (it can resist the typhoon of class 12), and it is fixed with anchor bolts as standard, with high safety.
Q: Is it compatible with the existing central air conditioning system?
A: It supports Modbus communication protocol, and can be connected to the building automation system (BAS) for unified management.
Q: How long does the filter need to be replaced?
A: The primary filter screen should be cleaned every 3 months, and the high-efficiency filter screen (such as HEPA) is recommended to be replaced every year, depending on the use environment.