Structure and working principle
Structural composition
Compressor: the core power component (scroll) to increase the pressure of refrigerant.
Condenser: air-cooled or water-cooled design, which releases heat through fins or coils.
Expansion valve: throttling and depressurizing to control refrigerant flow.
Control system: integrated pressure sensor, temperature controller and automatic protection device.
Working principle
Compression process: low-temperature and low-pressure gaseous refrigerant is pressurized and heated by compressor.
Condensation process: high temperature and high pressure gas is radiated and liquefied in the condenser.
Throttle evaporation: the liquid refrigerant is depressurized by the expansion valve, and then absorbs heat and evaporates to complete the cycle.
Product advantages and application scenarios
Product advantage
High efficiency and energy saving: adopting frequency conversion technology, the energy efficiency ratio (COP) reaches the leading level in the industry.
Stable and durable: fully enclosed compressor design, corrosion-resistant material to extend life.
Intelligent control: Support Internet of Things (IoT) remote monitoring and fault self-diagnosis.
Environmental compatibility: it is suitable for R410A refrigerants.
Application scenario
Industrial refrigeration: food processing, chemical reactor cooling.
Commercial field: central air conditioning in shopping malls/data centers.
Cold chain logistics: constant temperature control of cold storage and refrigerated trucks.
Technical parameters
Model | BDRF-22W | BDRF-28W | BDRF-35W | BDRF-45W | BDRF-53W | BDRF-61W | BDRF-70W | BDRF-105W | BDRF-150W | BDRF-300W | |||
Power supply | 380V 3N~50HZ | ||||||||||||
Ambient temperature | ℃ | -15~46 | |||||||||||
Power input | kW | 22 | 28 | 35 | 45 | 53 | 61 | 70 | 105 | 150 | 300 | ||
Nominal cooling capacity | kW | 7.1 | 9.6 | 11.3 | 15 | 18 | 20.1 | 22.6 | 36.2 | 48 | 96 | ||
Starting Current | A | 85 | 117 | 121 | 148.5 | 117 | 121 | 121 | 148.5 | 260 | 260 | ||
Max operatinc current | A | 19.3 | 23.7 | 28.5 | 35.5 | 44.5 | 50.6 | 68.4 | 79 | 105 | 210 | ||
Pipe size | Gas pipe | mm | 12.7 | 15.88 | 15.88 | 15.88 | 15.88 | 15.88 | 15.88 | 15.88 | 15.88 | 15.88 | |
Liquid pipe | mm | 22 | 28 | 28 | 28 | 28 | 28 | 28 | 28 | 35 | 35 | ||
Type | R410A | ||||||||||||
Refrigerant | Charging | 3.5kg | 4.0kg | 5.0kg | 5.5kg | 3.8kg*2 | 4.3kg*2 | 5.0kg*2 | 5.5kg*2 | 9.5kg*2 | 10kg*4 | ||
Noise | dB(A) | ≤65 | ≤67 | ≤69 | ≤70 | ≤73 | ≤76 | ≤76 | ≤78 | ≤74 | ≤78 | ||
Outline dimension | mm | 1036×1050×880 | 036×1050×100 | 126×1050×1000 | 176×1050×1000 | 1740×1036×100 | 900×1086×100 | 1940×136×1000 | 200×186×1002 | 270*1286*230 | 24502230*2230 | ||
Weight | kg | 135 | 170 | 180 | 200 | 340 | 370 | 450 | 510 | 850 | 1850 |
FAQ
Q: Too much noise when the unit is running?
A: Check whether the damping device of the compressor base is aging. It is recommended to replace the rubber pad regularly.
Q: What are the possible reasons for the decrease of condensation efficiency?
A: Most of them are dust accumulation on the radiator or refrigerant leakage, which needs to be cleaned or replenished after leak detection.
Q: How to choose air-cooled or water-cooled models?
A: Air cooling is selected in water-deficient areas, and water cooling is preferred for long-term high-load operation scenarios.
Structural composition
Compressor: the core power component (scroll) to increase the pressure of refrigerant.
Condenser: air-cooled or water-cooled design, which releases heat through fins or coils.
Expansion valve: throttling and depressurizing to control refrigerant flow.
Control system: integrated pressure sensor, temperature controller and automatic protection device.
Working principle
Compression process: low-temperature and low-pressure gaseous refrigerant is pressurized and heated by compressor.
Condensation process: high temperature and high pressure gas is radiated and liquefied in the condenser.
Throttle evaporation: the liquid refrigerant is depressurized by the expansion valve, and then absorbs heat and evaporates to complete the cycle.
Product advantage
High efficiency and energy saving: adopting frequency conversion technology, the energy efficiency ratio (COP) reaches the leading level in the industry.
Stable and durable: fully enclosed compressor design, corrosion-resistant material to extend life.
Intelligent control: Support Internet of Things (IoT) remote monitoring and fault self-diagnosis.
Environmental compatibility: it is suitable for R410A refrigerants.
Application scenario
Industrial refrigeration: food processing, chemical reactor cooling.
Commercial field: central air conditioning in shopping malls/data centers.
Cold chain logistics: constant temperature control of cold storage and refrigerated trucks.
Model | BDRF-22W | BDRF-28W | BDRF-35W | BDRF-45W | BDRF-53W | BDRF-61W | BDRF-70W | BDRF-105W | BDRF-150W | BDRF-300W | |||
Power supply | 380V 3N~50HZ | ||||||||||||
Ambient temperature | ℃ | -15~46 | |||||||||||
Power input | kW | 22 | 28 | 35 | 45 | 53 | 61 | 70 | 105 | 150 | 300 | ||
Nominal cooling capacity | kW | 7.1 | 9.6 | 11.3 | 15 | 18 | 20.1 | 22.6 | 36.2 | 48 | 96 | ||
Starting Current | A | 85 | 117 | 121 | 148.5 | 117 | 121 | 121 | 148.5 | 260 | 260 | ||
Max operatinc current | A | 19.3 | 23.7 | 28.5 | 35.5 | 44.5 | 50.6 | 68.4 | 79 | 105 | 210 | ||
Pipe size | Gas pipe | mm | 12.7 | 15.88 | 15.88 | 15.88 | 15.88 | 15.88 | 15.88 | 15.88 | 15.88 | 15.88 | |
Liquid pipe | mm | 22 | 28 | 28 | 28 | 28 | 28 | 28 | 28 | 35 | 35 | ||
Type | R410A | ||||||||||||
Refrigerant | Charging | 3.5kg | 4.0kg | 5.0kg | 5.5kg | 3.8kg*2 | 4.3kg*2 | 5.0kg*2 | 5.5kg*2 | 9.5kg*2 | 10kg*4 | ||
Noise | dB(A) | ≤65 | ≤67 | ≤69 | ≤70 | ≤73 | ≤76 | ≤76 | ≤78 | ≤74 | ≤78 | ||
Outline dimension | mm | 1036×1050×880 | 036×1050×100 | 126×1050×1000 | 176×1050×1000 | 1740×1036×100 | 900×1086×100 | 1940×136×1000 | 200×186×1002 | 270*1286*230 | 24502230*2230 | ||
Weight | kg | 135 | 170 | 180 | 200 | 340 | 370 | 450 | 510 | 850 | 1850 |
Q: Too much noise when the unit is running?
A: Check whether the damping device of the compressor base is aging. It is recommended to replace the rubber pad regularly.
Q: What are the possible reasons for the decrease of condensation efficiency?
A: Most of them are dust accumulation on the radiator or refrigerant leakage, which needs to be cleaned or replenished after leak detection.
Q: How to choose air-cooled or water-cooled models?
A: Air cooling is selected in water-deficient areas, and water cooling is preferred for long-term high-load operation scenarios.